Context 182 - December 2024

CONTEXT 182 : DECEMBER 2024 17 HEATING & VENTILATION and construction were included, the retrofit outperformed the new build for almost 60 years. In other words, it took almost 60 years for the lower day-to-day carbon running costs of the new-build to off-set its initial carbon costs. The Victorian terraced building is a relatively straightforward case which provides a model for a high proportion of historic buildings, including unlisted buildings in conservation areas. However, it would be wrong to conclude that all listed buildings could be subjected to the same level of alteration, particularly where fine interiors would be irreversibly altered. For many a balanced approach will be necessary, taking the easy wins first, like draught-stripping windows and doors, and increasing insulation in the roofs within safe parameters, without the risk of interstitial condensation. The rest must come mainly from reducing carbon in heating. Electric heating and heat‑pumps According to the National Grid, over 40 per cent of the UK’s electricity is currently generated by renewables annually, including wind power in particular, and the proportion is set to rise further. An additional 15 per cent is currently generated by nuclear power. Gas and nuclear power stations will continue to be part of the mix as energy from solar and wind farms varies with the weather. However, currently no power stations in the UK capture their carbon, and most of the UK’s nuclear power stations will be decommissioned before 2030. In her autumn budget, Chancellor Rachel Reeves announced funding for investment in carbon capture and storage. This includes nearly £22 billion to support the development of two undersea carbon storage sites and pipelines, with the capacity to store more than 8.5 million tonnes of carbon dioxide a year (in 2022, carbon dioxide emissions from power stations stood at 53.7 million tonnes). Other measures Reeves announced included investment in nuclear energy and the production of green hydrogen using renewable electricity. As electricity currently stands, simply switching from a fossil-fuel heating system to electricity would reduce carbon emissions from heating by over 55 per cent in the short term. This saving increases to around 75 per cent if a heat‑pump is used to extract heat from an existing source. A heat‑pump works on the same principle as a fridge, using the temperature change which occurs when a material changes phase to move heat from one place to another. A fluid is chosen which is a gas at all outside temperatures but becomes a liquid when pressurised. This chemical, known as the ‘refrigerant’, is circulated between two heat exchangers, one inside and the other outside. As it vapourises in the outer RENEWABLE SOURCES OF ELECTRICITY IN 2023 AS A PROPORTION OF THE UK’S TOTAL ELECTRICITY GENERATION Energy source Proportion (%) Wind power 29 Biomass energy (from burning renewable organic materials) 5 Solar power 5 Hydropower, including tidal 2 Source: National Grid A further 15 per cent is generated by nuclear energy (not technically a renewable), but most of the UK’s aging nuclear power stations will be decommissioned by the end of this decade, pending the development of new ones. one the temperature drops rapidly, allowing the gas to rapidly absorb heat from its surroundings. This could be through a long network of pipes running underground (a ground-source heat‑pump), or in a lake or stream (watersource), but the simplest to install is an airsource heat‑pump with a fan blowing air over the heat exchanger. The warmed gas then passes through a pump which pressurises it, causing it to revert to its liquid phase, releasing heat into the interior of the building, including all the heat it picked up along the way. In a well-designed system, far less energy is used to pressurise the fluid than is released in thermal energy. The ratio of energy expended in electricity to the thermal energy gained, known as its coefficient of performance (COP), will vary according to the efficiency of the heat exchanger and the temperature of the heat source. A gas-fired boiler, for example, will have a COP of a little less than one, as some An air-source heat‑pump typically produces significantly more energy than it uses in even the coldest weather. (Photo: Tom Dixon-Smith, Ultra-Fin)

RkJQdWJsaXNoZXIy MjgyMjA=